Wireless Watch Type Personal Dosimeter Sound And Light Alarm Dose Rate Radiation Measurement

Menşe yeri Pekin
Marka adı HUATEC
Sertifika ISO, CE, GOST
Model numarası HRD-3
Min sipariş miktarı 1 adet
Ambalaj bilgileri Standart İhracat Paketi
Teslim süresi 1-4 gün
Ödeme koşulları T/T, PayPal, Western Union
Yetenek temini ayda 500 adet

Ücretsiz numuneler ve kuponlar için bana ulaşın.

Naber:0086 18588475571

WeChat: 0086 18588475571

Skype: sales10@aixton.com

Eğer herhangi bir endişeniz varsa, 24 saat online yardım sağlıyoruz.

x
Ürün ayrıntıları
Ölçüm aralığı Kümülatif doz Hp(10): 0.0mSv~10Sv;Doz hızı Hp (10): 1mSv/h~500mSv/h bağıl hata <±10% (1mSv/h,Cs-137)
Enerji tepkisi <±30%(50keV1.5MeV) Alarm yöntemi Sesli ve ışıklı alarm ve LCD ekran göstergesi
Görünüm boyutu Φ49㎜×16㎜ (bileklik hariç) Yanıt doğrusallığı <±20% (10Sv/h500mSv/h)
aşırı yük özellikleri >10Sv/h Ağırlık 45g
Veri iletişimi veri depolama, sistem yönetimi için bilgisayara kablosuz olarak iletilir Veri depolama işlevi Cihaz kapatıldığında, ölçüm verileri güç kaybı olmadan saklanacaktır.
Ürün Adı kişisel dozimetre Uygulama saat tipi doz hızı ölçümü
Vurgulamak

wireless watch type personal dosimeter

,

sound and light alarm personal dosimeter

Mesaj bırakın
Ürün Açıklaması

Wireless Watch Type Sound And Light Alarm Personal Dosimeter Dose Rateradiation Measurement

 

General introduction

Wrist-type personal dosimeter is mainly used to monitor X γ, it particularly suitable for the medical application of interventional radiotherapy. The dosimeter is controlled by a low-power single-chip microcomputer, which realizes LCD drive display, measurement data storage, relevant parameter setting, detector fault alarm, battery voltage detection, over-threshold acoustooptic alarm, wireless communication, wireless charging and other functions.

 

Main technical indicators

Detector Silicon semiconductor detector
Measuring range Hp(10): 0.0Sv10Sv
H’p(10): 1Sv/h1Sv/h
Alarm threshold

Hp(10): 1continuously adjustable between Sv10Sv

H’p(10): 1continuously adjustable between Sv/h1Sv/h

Alarm

Alarm sound-light and LCD indication alarm, and the cumulative dose and dose rate exceed the threshold, Battery undervoltage, working overtime and detector failure alarm

Audio-visual indication of different cumulative dose increments

LCD display

Hp(10): 0.0Sv9999mSv

H’p(10): 0.05Sv/h9999mSv/h

Energy response <±30%(50keV1.5MeV)
Angle response

Am-241(60keV),<±50%(0°~75°)

Cs-137(662keV),<±20%(0°~75°)

Response linearity <±20% (1Sv/h1Sv/h)
Relative inherent error <±10% (2mSv/h,Cs-137)
Overload characteristic >10Sv/h
Power supply rechargeable lithium battery (3.7V, 100mAh), continuous operation 240h
Under voltage indication can still work for more than 8 hours after battery under voltage indication
Temperature characteristic <± 15%, @ - 10 ℃~+40 ℃
Humidity characteristics <±15%, 40%90%RH@35℃
Weight 80g
Size about 50 mm × 40 mm (excluding strap)
Power consumption of the whole machine about 0.3mA (excluding audible and visual alarm)
Data storage The instrument stores measurement data when it is powered off, and does not lose when it is powered off

 

 

Structure diagram

 

Name of each part of the instrument:

 

Wireless Watch Type Personal Dosimeter Sound And Light Alarm Dose Rate Radiation Measurement 0

 

① LCD: segment code LCD ② Set key (SET)

③ Mode key (MODE) ④ Backlight key (LIGHT)

⑤ Function key (FUNC) ⑥ Detector location identification

⑦ Buzzer hole ⑧ Watchband

 

Standard accessories

HRD-3 dosimeter

Wireless charger/wireless communication

Rechargeable lithium battery(4.2V,100mAh)

Instruction manual

Calibration certificate

Box

 

Application field:

It is applicable to the protection and personal dose monitoring of workers in the fields of industrial nondestructive testing, isotope application, nuclear industry, hospital, railway, civil aviation, environmental protection and other radioactive applications